From a single rack to a hyperscale campus

  • AirUp to 30 kW a rack
  • Rear-door30–60 kW a rack
  • Direct-to-chip liquid60–150 kW a rack
  • Immersion150 kW and more
01Size your space

You need the space. We’ll find the room

Move the sliders, or start from a tenant like you.

Every rack comes with

  • A and B power feeds, metered
  • Cross-connects to our network, AS215724
  • Remote hands around the clock
  • Biometric access, CCTV and staff on site
  • A 99.999% uptime SLA
  • Room to grow in the same facility
Start from

40Racks

2.4MWTotal IT load

Racks
kW a rack
Format
Suite
Cooling
Rear-door
Ready
8–12 weeks
Room for
An HGX B300 rack

Typical ranges. Each facility sets its own limit.

Figures are estimates for illustration, not a quote. Real pricing depends on the site, power and contract.

02Formats

Start with a rack. Grow to a campus

The same contract, the same network and the same team at every size.

  1. Your space

    Cabinet

    A single locked rack in a shared hall.

    Power
    5–30 kW
    Size
    1 rack
    Ready
    From 2 weeks

    01 / 05

  2. Your space

    Cage

    Your racks behind your own mesh walls.

    Power
    30 kW–1 MW
    Size
    5–40 racks
    Ready
    From 4 weeks

    02 / 05

  3. Your space

    Suite

    A private room with its own power and cooling.

    Power
    1–5 MW
    Size
    40–200 racks
    Ready
    8–12 weeks

    03 / 05

  4. Your space

    Hall

    A whole data hall, built out for your density.

    Power
    5–20 MW
    Size
    A full hall
    Ready
    3–6 months

    04 / 05

  5. Your space

    Campus

    A campus of halls, built to suit on our powered land.

    Power
    20 MW and more
    Size
    Many halls
    Ready
    12–24 months

    05 / 05

03Network

Your cage is one hop from the internet

Every facility connects to our own network, AS215724.

An aluminium model of the path out: a mesh cage of racks with a fibre tray overhead, a fibre conduit to an internet exchange with router racks, a cloud data center and a cluster of city towers.
04Resilience

Built to stay on

Standard in every facility, more where you need it. Certifications vary by facility.

One spare in every chain: a generator, a UPS module and a cooling unit more than the load needs.

Power
N+1 UPS and generators
Cooling
N+1
Uptime SLA
99.999%
Security
Biometric access, 24/7 staff, CCTV
Certifications
By facility
Remote hands
24/7
A data center’s power chain at dusk: transmission lines into a substation yard, a row of generator containers, and the building cut open on its switchgear, UPS room and data hall; one train lit with a spare, the second transformers and cabinets dark.